How to check the existing piping settings
You can check whether the existing piping settings are enabled.
1. Check that the LED displays are placed in their initial status. If not, place them in the initial status.
2. Hold down SW01 for at least 5 seconds, and check that D804 flashes slowly. (Fig. 9)
3. Press SW01 four times to set the LED displays (D800 to D805) to the “LED displays for existing piping settings”
shown below. If the setting is enabled, D802 lights and D804 and D805 flash rapidly. (Fig. 10)
4. Hold down SW01 and SW02 simultaneously for at least 5 seconds to return the LED displays to the initial status.
(Fig. 9)
: ON, : OFF, : Slow flashing
(Fig. 10)
: ON, : OFF, : Rapid flashing
When restoring the factory defaults
To restore the factory defaults in situations such as when relocating the units, follow the steps below.
1. Check that the LED displays are placed in their initial status. If not, place them in the initial status.
2. Hold down SW01 for at least 5 seconds, and check that D804 flashes slowly. (Fig. 11)
3. Press SW01 14 times to set the LED displays (D800 to D805) to the “LED displays restored to factory defaults”
shown below. (Fig. 12)
(Fig. 11)
: ON, : OFF, : Slow flashing
(Fig. 12)
: ON, : OFF, : Rapid flashing
4. Hold down SW02 for at least 5 seconds, and check that D804 flashes slowly. (Fig. 13)
5. Hold down SW01 and SW02 simultaneously for at least 5 seconds to return the LED displays to the initial status.
(Fig. 13)
: ON, : OFF, : Slow flashing
LED displays indicated when step 3 is taken
D800 D801 D802 D803 D804 D805
LED displays for existing piping settings
D800 D801 D802 D803 D804 D805
LED displays indicated when step 2 is taken
D800 D801 D802 D803 D804 D805
LED displays restored to factory defaults
D800 D801 D802 D803 D804 D805
LED displays indicated when step 4 is taken
D800 D801 D802 D803 D804 D805
14
Troubleshooting
You can perform fault diagnosis of the outdoor unit with the LEDs on the P.C. board of the outdoor unit in addition
to using the check codes displayed on the wired remote controller of the indoor unit.
Use the LEDs and check codes for various checks. Details of the check codes displayed on the wired remote
controller of the indoor unit are described in the Installation Manual of the indoor unit.
LED displays and check codes
: ON, : OFF, : Rapid flashing (5 times/sec.)
rorrE.oN
Display
D800 D801 D802 D803 D804 D805
1Normal
2 Discharge temperature sensor (TD) error
3 Heat exchanger temperature sensor (TE) error
4 Heat exchanger temperature sensor (TL) error
5 Outside air temperature sensor (TO) error
6 Suction temperature sensor (TS) error
7 Heat sink temperature sensor (TH) error
8 Heat exchanger sensor (TE, TS) connection error
9 EEPROM error
10 Compressor breakdown
11 Compressor lock
12 Current detection circuit error
13 Case thermostat operation
14 Model data not set
15 Discharge temperature error
16 Power supply error
17 High pressure SW error
18 Heat sink overheating error
19 Ga
s leak detected
20 4-way valve reverse error
21 High pressure release operation
22 Fan system error
23 Drive device short-circuiting
24 Position detection circuit error
25 Compressor IPDU or other (not specifically identified)
* The LEDs and switches are located at the top right of
the P.C. board of the outdoor unit as shown in the
figure on the right.
LED displays
D800 D801 D802 D803 D804 D805
(Yellow) (Yellow) (Yellow) (Yellow) (Yellow) (Green)
1115150101_EN.indd 391115150101_EN.indd 39 8/24/13 9:40 AM8/24/13 9:40 AM
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44

Comments to this Manuals

No comments