How to open the valve
Open or close the valve.
Liquid side, gas side
Open the valve with hexagon wrench.
[Hexagonal wrench is required.]
Valve handling precautions
Open the valve stem until it strikes the stopper.
It is unnecessary to apply further force.
Securely tighten the cap with a torque wrench.
Cap tightening torque
Replenishing refrigerant
This model is a 20 m chargeless type that does not
need to have its refrigerant replenished for refrigerant
pipes up to 20 m. When a refrigerant pipe longer than
20 m is used, add the specified amount of refrigerant.
Refrigerant replenishing procedure
1. After vacuuming the refrigerant pipe, close the
valves and then charge the refrigerant while the air
conditioner is not working.
2. When the refrigerant cannot be charged to the
specified amount, charge the required amount of
refrigerant from the charge port of the valve on the
gas side during cooling.
Requirement for replenishing refrigerant
Replenish liquid refrigerant.
When gaseous refrigerant is replenished, the
refrigerant composition varies, which disables normal
operation.
Adding additional refrigerant
L: Pipe length
The refrigerant need not be reduced for a 20 meter
(or less) refrigerant pipe.
Hexagonal wrench size
Liquid side
Gas side
SM56 4 mm 4 mm
SM80 4 mm 5 mm
Valve size
Ø6.4 mm
14 to 18 1P
(1.4 to 1.8 kgfm)
Ø9.5 mm
14 to 18 1P
(1.4 to 1.8 kgfm)
Ø12.7 mm
33 to 42 1P
(3.3 to 4.2 kgfm)
Ø15.9 mm
33 to 42 1P
(3.3 to 4.2 kgfm)
Charge port
14 to 18 1P
(1.4 to 1.8 kgfm)
21~30 m: L
SM56 20 g × (L-20)
SM80 40 g × (L-20)
7
Electrical work
CAUTION
An installation fuse must be used for the power supply
line of this air conditioner.
Incorrect / incomplete wiring may lead to an electrical
fire or smoke.
Prepare an exclusive power supply for the air
conditioner.
This product can be connected to the mains power.
Fixed wire connections:
A switch that disconnects all poles and has a contact
separation of at least 3 mm must be incorporated in
the fixed wiring.
Be sure to use the cord clamps attached to the
product.
Do not damage or scratch the co
nductive core or inner
insulator of the power and system interconnection
wires when peeling them.
Use the power and system interconnection wires with
specified thicknesses, specified types and protective
devices required.
1 Remove valve cover screw.
2 Pull the valve cover downward to remove it.
Wiring between indoor unit
and outdoor unit
The dashed lines show on-site wiring.
Connect the system interconnection wires to the
identical terminal numbers on the terminal block of
each unit.
Incorrect connection may cause a failure.
For the air conditioner, connect a power wire with the
following specifications.
Valve cover
Power supply wire
System
interconnection
wires
Model RAV- SM56, SM80
Power supply
220-240 V~, 50 Hz
220 V~, 60 Hz
Maximum running current 15.5 A
Installation fuse rating 20 A (all types can be used)
Power supply wire
H07 RN-F or 60245 IEC 66
(2.5 mm
2
or more)
System interconnection
wires
H07 RN-F or 60245 IEC 66
(1.5 mm
2
or more)
L
N
1
2
3
1
2
3
(System
interconnection wires)
Input power
Earth
(Main circuit)
Remote
controller
Indoor unitOutdoor unit
Circuit
breaker
1115150101_EN.indd 351115150101_EN.indd 35 8/24/13 9:40 AM8/24/13 9:40 AM